gallery-image
gallery-image
ImageCount

1 / 3

مولد بيركنز Perkins Generator 30 KVA

AED 32,800

logo
Toulba
2 items live

Item Details

Condition

Perfect inside and out

Usage

Still in original packaging

Posted on: 14th May 2026


Description

Standard Specifications:
1- Prime Rating:
Unlimited hours usage, with an average
load factor of 80% over each 24 hour period. 10% overload is available for 1 hour in
every 12 hours operation. 0 overload is
permitted on standby power.
2- Standby Rating:
Limited to 500 hours annual usage, with an
average load factor of 80% of the published standby power rating over each 24
hour period. Up to 300 hours of annual
usage may be run continuously. No overload is permitted on standby power.
3- Engine:
Perkins, including air filters, fuel filters,
oil filter, starting motor and charging alternator etc.
4- Alternator Type:
brushless AC alternator
5- Radiator:
50°C, fan protective shroud
6– Fuel Tank:
Capacity of fuel tank is for 8-10 hours
running
Built in fuel tank up to 800 kVA
7- Circuit Breaker:
3 pole LS MCCB
8– Control system alarms:

Over and Under Speed
Large back-lit text display
Multiple display languages
DSENET expansion compatible
Data logging facility
Fully configurable via PC using USB
communication
Front panel configuration
Efficient power save mode
3 phase generator sensing
Accumulated power monitoring (kWh, kVA h,
kVAr h)
Generator/load current monitoring and
protection (kW)
Breaker contol via fascia buttons
Fuel and start outputs, configurable using
can
4 configurable DC outputs
4 configurable analogue/digital inputs
Automatically transfers between mains (utility)
and generator
Increased input and output expansion
capability via dsenet
IP65 rating (with optional gasket) offers
increased resistance to water ingress
Digital inputs; Analogue Inputs

Low and High Battery Volt.

Start and Stop Failure

Over Current

Under / Over Generator Voltage

Low Oil Pressure

Emergency stop

High engine temperature
DSE4520 MKII
AUTO START & AUTO MAINS
FAILURE CONTROL
9– Warranty policy:

GENERATOR products has a
warranty for 12 Months or 1000
hours whichever occurs first
against any manufacturing defects

Wearing parts (filters), incorrect
man made operation, maintenance failures are excluded from
the warranty policy
Acoustic Enclosure Specifications:
Enclosure Type
Acoustic & Weather
Proof
Drainage Provision
Fuel and Water Drainage
Tested Single Point Lifting
Transportation
Facility&Forklift Pockets
Ingress Protection Rating IP 23
Lifting
ISO Standard Lifting
Canopy RAL Color
TAL 9010
Base frame RAL Color
RAL 9011
Noise Pressure level @ 7m 69 dB(A)
Perkins heavy duty high performance industrial type diesel engine.
Engine:
Optional configurations:
Engine accessories:
Heavy-duty air filter
Coolant heater
Lubricant oil heater
Fuel and Water Separator
Lube oil rotary pump
Alternator And Accessories:
Leroy somer/stamford
Anti condensation heater
PMG + AVR ◇
Double bearing
alternator High voltage
kV
RTDs for Bearing and winding
Cooling System:
55 degree Radiator
Remote Radiator
Control System:
AMF
Parallel
Practical type in low temperature environment
Control Screen Heater
Remote Annunciators Other(
ComP, DEIF)
Circuit Breaker:
3/4 poles
Fixed/handcarttype
Electric mechanism
Automatic Transfer Switch (ATS):
ATS cabinet
Contractor type ATS
Motorized changeover type ATS
Start Battery:
Nickel-cadmium battery
Maintenance-free battery
Battery charger and selector switch
Charging current meter
External Fuel Tank:
Single /double wall fuel tank (500-5000 L)
Fuel Transfer pump
Exhaust Muffler:
Residential grade
Critical grade
Hospital grade
Available for voltages :
400/230V, 480/277V, 380/220V, 440/254V,
416/240V,220/127V, 208/120V
De-rating may apply.
COOLING SYSTEM
Total Coolant Capacity (L)
Cooling Fan Air Flow
Radiator Fan Load
Heat Radiation to Room (PRP)
Heat Radiation to Room (ESP)
LUBRICATIONSYSTEM
Oil Filter Type
TotalOil Capacity
Oil Type
EXHAUST SYSTEM
Muffler Type
Max. Back Pressure
ExhaustGas Flow (PRP/ESP)
Exhaust Gas Temperature
10.2 L
53 m3/ min
0.4 kW
5.0 kW
6.0 kW
Spin-On Full Flow
8.3L
API-CH-4 or ACEA E5
Industrial Grade
8 kPa
5.7/5.8 m3/ min
< 5200C
FUEL SYSTEM
Recommended Fuel
Class A2 Diesel
Fuel Consumption Standby
8.1 L/hr
Fuel Consumption 100% PRP
7.2 L/hr
Fuel Consumption 75% PRP
5.6 L/hr
Fuel Consumption 50% PRP
4.0 L/hr
AIR SYSTEM
Air Filter Type
Dry Element
Combustion Air Flow (PRP)
2.15 m3/min
Combustion Air Flow (ESP)
2.16m3/min
Max Air Filter Intake Restriction
3kPA

Location

Industrial Area 6, Industrial Area, Sharjah, UAE


UAE
chevronClassifieds
  • Motors
  • Property for Rent
  • Property for Sale
  • Classifieds
  • Furniture & Garden
  • Mobiles & Tablets
  • Jobs
  • Community
  • Used Cars
  • New Cars
  • Export Cars
  • Rental Cars
  • Motorcycles
  • Auto Accessories & Parts
  • Heavy Vehicles
  • Boats
  • Number Plates
العربية